Glass Thickness & Build-Up
Model monolithic and laminated glass build-ups, including interlayers, pane thickness, and configuration details.
For Facade Engineers, Glazing Contractors & Architects
Use VitraLab for structural glazing calculations through separate EN 16612 and draft-based Eurocode 10 routes. Check glass weight, laminated glass, EC10 EET and partial shear coupling, DGU and TGU systems, ULS stress, and SLS deflection under wind, snow, live, maintenance, barrier, and accidental actions.
Enter the glass build-up and project loads, then review combinations, governing results, stress, deflection, and utilization.
Model monolithic and laminated glass build-ups, including interlayers, pane thickness, and configuration details.
Use pane dimensions and configuration data to support glass weight, dead load, and structural glass design checks.
Apply wind, snow, live, maintenance, accidental, and barrier loads using separate, visible inputs.
Review ultimate limit state stress effects and governing load combinations for glass design.
Check serviceability deflection limits with reported values, utilization, and pass/fail results.
View calculation summaries, utilization, pane results, and detailed ULS/SLS combination effects.
VitraLab is intended for facade engineers, glazing contractors, architects, and others who need to review structural glass calculations.
Run structural glass checks, review load combinations, and compare ULS/SLS output for facade elements.
Check practical glass build-ups, pane dimensions, and load cases before progressing design coordination.
Understand glass feasibility, approximate build-ups, and structural limits earlier in the design process.
VitraLab supports the design checks typically needed for glass in facades, roofs, balustrades, partitions, and other glazed elements.
Ultimate limit state stress effects and governing design combinations.
Serviceability checks with stated deflection limits and result summaries.
Separate loading conditions for horizontal and vertical glass.
Pane-level results for common glass configurations, including EET laminated panes and TGU within the implemented EC10 scope.
Load inputs aligned with practical facade and glazing design scenarios.
VitraLab references European design standards while keeping National Annex values editable for the project location.
Structural glass design support for stress and deflection verification.
Separate EC10 calculations based on the reviewed 2024 drafts of prEN 19100-1 and prEN 19100-2. The documents are not final published standards.
Basis of structural design and load combination principles.
Actions on structures for imposed loads and relevant design actions.
Barrier load defaults currently use Irish National Annex categories and can be adjusted for project or local National Annex requirements.
Custom barrier load values can be entered where project-specific or local National Annex requirements apply.
Read practical examples and topic guides, then open the calculator to check your own inputs.