VitraLab Aluminium
1. Action
Enter the design punching force already distributed to one bolt. Bolt shear, bearing, tension, net section, and local washer checks remain separate checks.
2. Bearing diameter
If washers are used, dm is limited to the washer outer diameter where it is smaller than the mean bolt head or nut dimension.
3. Aluminium member
tp is the thickness of the plate under the bolt head or nut being checked.
4. Formula guide
Formula: Bp,Rd = 0.6 π dm tp fu / γM2
dm is the mean of across-points and across-flats dimensions of the bolt head or nut. If washers are used, the washer outer diameter is used where it is smaller.
5. Result
6. Code notes
7. Report preview